Changing Engine Crankcase Filter Element
Remove filter element (A) and clean mounting surface (B).
Apply a thin film of oil to sealing ring (C) of new filter. Tighten new filter element until sealing ring touches mounting surface and then turn an additional
3
/
4
to 1
1
/
4
turns. Do not overtighten!
Start engine and check base of filter for leaks.
Shut off engine and check oil level.
NOTE:
Carry out first oil filter change after first 100 hours of operation.
|