Oil Withdrawal With Hydraulic Motor

Maximum obtainable oil flow of transmission/hydraulic oil is 60 l/min (15.9 gpm).

NOTE: Use left hand-mounted selective control valves only.

Shut off the engine. Move the corresponding SCV control lever to the "float" position. Connect the hydraulic hose from the hydraulic motor.

NOTE: When the control lever is pushed forward (or to the right in case of the multi-function lever), pressure is applied to the upper union.

Start the engine. Move the control lever to "lower".

To switch off the hydraulic motor, move the control lever to the "float" position. Shut off the engine and take out the hydraulic hose.

IMPORTANT: Do not move the control lever to the "neutral" position, as this may result in back-pressure causing damage to the hydraulic motor and hoses.

AG,OU12401,34 -19-14DEC99-1/1