Diagnostic Trouble Codes on E-ICV and E-SCV Controller (SIC)
| Light |
Diagnostic trouble code |
Description |
| blue |
SIC 000629.12 |
Controller internal fault |
| blue |
SIC 000639.12 |
Controller internal fault |
| blue |
SIC 000639.13 |
29-bit CAN BUS, high error rate |
| blue |
SIC 000639.14 |
29-bit CAN BUS (Tractor BUS), very high error rate |
| blue |
SIC 000639.19 |
29-bit CAN BUS, very high error rate |
| blue |
SIC 334001.09 |
Engine control unit or basic control unit has stopped sending data (engine speed) |
| blue |
SIC 334002.09 |
Basic control unit has stopped transmitting data (engine operating hours) |
| blue |
SIC 334003.09 |
Transmission control unit or BIF is/are not sending any data (hydraulic oil temperature) |
| blue |
SIC 334010.01 |
Hydraulic oil temperature too low |
| blue |
SIC 334028.14 |
Controller not calibrated |
| blue |
SIC 334041.31 |
E-ICV no.1, potentiometer at multi-function lever faulty |
| blue |
SIC 334042.31 |
E-ICV no.2, potentiometer at multi-function lever faulty |
| blue |
SIC 334043.31 |
E-ICV no.3, potentiometer at multi-function lever faulty |
| blue |
SIC 334044.31 |
E-SCV no.1, potentiometer at control lever faulty |
| blue |
SIC 334045.31 |
E-SCV no.2, potentiometer at control lever faulty |
| blue |
SIC 334046.31 |
E-SCV no.3, potentiometer at control lever faulty |
| blue |
SIC 334047.31 |
E-SCV no.4, potentiometer at control lever faulty |
| blue |
SIC 334051.14 |
E-ICV no.1, potentiometer or switch at multi-function lever is faulty |
| blue |
SIC 334051.31 |
E-ICV no.1, switch at multi-function lever faulty |
| blue |
SIC 334052.14 |
E-ICV no.2, potentiometer or switch at multi-function lever is faulty |
| blue |
SIC 334052.31 |
E-ICV no.2, switch at multi-function lever faulty |
| blue |
SIC 334053.14 |
E-ICV no.3, potentiometer or switch at multi-function lever is faulty |
| blue |
SIC 334053.31 |
E-ICV no.3, switch at multi-function lever faulty |
| blue |
SIC 334054.14 |
E-SCV no.1, potentiometer or switch at control lever is faulty |
| blue |
SIC 334054.31 |
E-SCV no.1, switch at control lever faulty |
| blue |
SIC 334055.14 |
E-SCV no.2, potentiometer or switch at control lever is faulty |
| blue |
SIC 334055.31 |
E-SCV no.2, switch at control lever faulty |
| blue |
SIC 334056.14 |
E-SCV no.3, potentiometer or switch at control lever is faulty |
| blue |
SIC 334056.31 |
E-SCV no.3, switch at control lever faulty |
| blue |
SIC 334057.14 |
E-SCV no.4, potentiometer or switch at control lever is faulty |
| blue |
SIC 334057.31 |
E-SCV no.4, switch at control lever faulty |
| blue |
SIC 334059.31 |
5-volt power supply is faulty |
| blue |
SIC 334060.14 |
E-ICV, transport lock switch is faulty |
| blue |
SIC 334061.14 |
E-ICV, safety switch is faulty |
| blue |
SIC 334062.14 |
E-SCV, transport lock switch is faulty |
| blue |
SIC 334106.12 |
Controller internal fault |
| blue |
SIC 334136.18 |
E-ICV no.1-stepper motor, supply voltage too low |
| blue |
SIC 334137.01 |
E-ICV no.1-stepper motor, supply voltage very low |
| blue |
SIC 334138.00 |
E-ICV no.1-stepper motor, supply voltage too high |
| blue |
SIC 334139.14 |
E-ICV no.1-stepper motor, no connection to controller |
| blue |
SIC 334140.14 |
E-ICV no.1-stepper motor, coil temperature too low |
| blue |
SIC 334141.14 |
E-ICV no.1-stepper motor, coil temperature too high |
| blue |
SIC 334144.18 |
E-ICV no.2-stepper motor, supply voltage too low |
| blue |
SIC 334145.01 |
E-ICV no.2-stepper motor, supply voltage very low |
| blue |
SIC 334146.00 |
E-ICV no.2-stepper motor, supply voltage too high |
| blue |
SIC 334147.14 |
E-ICV no.2-stepper motor, no connection to controller |
| blue |
SIC 334148.14 |
E-ICV no.2-stepper motor, coil temperature too low |
| blue |
SIC 334149.14 |
E-ICV no.2-stepper motor, coil temperature too high |
| blue |
SIC 334152.18 |
E-ICV no.3-stepper motor, supply voltage too low |
| blue |
SIC 334153.01 |
E-ICV no.3-stepper motor, supply voltage very low |
| blue |
SIC 334154.00 |
E-ICV no.3-stepper motor, supply voltage too high |
|
|
OULXE59,00107E9 -19-26JUL05-1/2
|
| Light |
Diagnostic trouble code |
Description |
| blue |
SIC 334155.14 |
E-ICV no.3-stepper motor, no connection to controller |
| blue |
SIC 334156.14 |
E-ICV no.3-stepper motor, coil temperature too low |
| blue |
SIC 334157.14 |
E-ICV no.3-stepper motor, coil temperature too high |
| blue |
SIC 334160.18 |
E-SCV no.1-stepper motor, supply voltage too low |
| blue |
SIC 334161.01 |
E-SCV no.1-stepper motor, supply voltage very low |
| blue |
SIC 334162.00 |
E-SCV no.1-stepper motor, supply voltage too high |
| blue |
SIC 334163.14 |
E-SCV no.1-stepper motor, no connection to controller |
| blue |
SIC 334164.14 |
E-SCV no.1-stepper motor, coil temperature too low |
| blue |
SIC 334165.14 |
E-SCV no.1-stepper motor, coil temperature too high |
| blue |
SIC 334168.18 |
E-SCV no.2-stepper motor, supply voltage too low |
| blue |
SIC 334169.01 |
E-SCV no.2-stepper motor, supply voltage very low |
| blue |
SIC 334170.00 |
E-SCV no.2-stepper motor, supply voltage too high |
| blue |
SIC 334171.14 |
E-SCV no.2-stepper motor, no connection to controller |
| blue |
SIC 334172.14 |
E-SCV no.2-stepper motor, coil temperature too low |
| blue |
SIC 334173.14 |
E-SCV no.2-stepper motor, coil temperature too high |
| blue |
SIC 334176.18 |
E-SCV no.3-stepper motor, supply voltage too low |
| blue |
SIC 334177.01 |
E-SCV no.3-stepper motor, supply voltage very low |
| blue |
SIC 334178.00 |
E-SCV no.3-stepper motor, supply voltage too high |
| blue |
SIC 334179.14 |
E-SCV no.3-stepper motor, no connection to controller |
| blue |
SIC 334180.14 |
E-SCV no.3-stepper motor, coil temperature too low |
| blue |
SIC 334181.14 |
E-SCV no.3-stepper motor, coil temperature too high |
| blue |
SIC 334184.18 |
E-SCV no.4-stepper motor, supply voltage too low |
| blue |
SIC 334185.01 |
E-SCV no.4-stepper motor, supply voltage very low |
| blue |
SIC 334186.00 |
E-SCV no.4-stepper motor, supply voltage too high |
| blue |
SIC 334187.14 |
E-SCV no.4-stepper motor, no connection to controller |
| blue |
SIC 334188.14 |
E-SCV no.4-stepper motor, coil temperature too low |
| blue |
SIC 334189.14 |
E-SCV no.4-stepper motor, coil temperature too high |
| blue |
SIC 334201.14 |
E-ICV no.1, stepper motor does not start |
| blue |
SIC 334202.14 |
E-ICV no.2, stepper motor does not start |
| blue |
SIC 334203.14 |
E-ICV no.3, stepper motor does not start |
| blue |
SIC 334204.14 |
E-SCV no.1, stepper motor does not start |
| blue |
SIC 334205.14 |
E-SCV no.2, stepper motor does not start |
| blue |
SIC 334206.14 |
E-SCV no.3, stepper motor does not start |
| blue |
SIC 334207.14 |
E-SCV no.4, stepper motor does not start |
| blue |
SIC 334221.14 |
E-ICV no.1, stepper motor does not respond to command from controller |
| blue |
SIC 334222.14 |
E-ICV no.2, stepper motor does not respond to command from controller |
| blue |
SIC 334223.14 |
E-ICV no.3, stepper motor does not respond to command from controller |
| blue |
SIC 334224.14 |
E-SCV no.1, stepper motor does not respond to command from controller |
| blue |
SIC 334225.14 |
E-SCV no.2, stepper motor does not respond to command from controller |
| blue |
SIC 334226.14 |
E-SCV no.3, stepper motor does not respond to command from controller |
| blue |
SIC 334227.14 |
E-SCV no.4, stepper motor does not respond to command from controller |
| blue |
SIC 334240.14 |
Controller is connected to the wrong harness connector |
|
|
OULXE59,00107E9 -19-26JUL05-2/2
|
|