Diagnostic Trouble Codes on E-ICV Controller (SIC)

Light Diagnostic trouble code Description
blue SIC 000629.12 Controller internal fault
blue SIC 000639.12 Controller internal fault
blue SIC 000639.13 29-bit CAN BUS, high error rate
blue SIC 000639.19 29-bit CAN BUS, very high error rate
blue SIC 334001.09 Engine control unit or basic control unit has stopped sending data (engine speed)
blue SIC 334002.09 Basic control unit has stopped transmitting data (engine operating hours)
blue SIC 334003.09 Transmission control unit or BIF is/are not sending any data (hydraulic oil temperature)
blue SIC 334010.01 Hydraulic oil temperature too low
blue SIC 334028.14 Controller not calibrated
blue SIC 334041.31 E-ICV no.1, potentiometer at multi-function lever faulty
blue SIC 334042.31 E-ICV no.2, potentiometer at multi-function lever faulty
blue SIC 334043.31 E-ICV no.3, potentiometer at multi-function lever faulty
blue SIC 334051.14 E-ICV no.1, switch at multi-function lever faulty
blue SIC 334052.14 E-ICV no.2, switch at multi-function lever faulty
blue SIC 334053.14 E-ICV no.3, switch at multi-function lever faulty
blue SIC 334059.31 5-volt power supply is faulty
blue SIC 334060.14 E-ICV, transport lock switch is faulty
blue SIC 334061.14 E-ICV, safety switch is faulty
blue SIC 334106.12 Controller internal fault
blue SIC 334136.18 E-ICV no.1-stepper motor, supply voltage too low
blue SIC 334137.01 E-ICV no.1-stepper motor, supply voltage very low
blue SIC 334138.00 E-ICV no.1-stepper motor, supply voltage too high
blue SIC 334139.14 E-ICV no.1-stepper motor, no connection to controller
blue SIC 334140.14 E-ICV no.1-stepper motor, coil temperature too low
blue SIC 334141.14 E-ICV no.1-stepper motor, coil temperature too high
blue SIC 334144.18 E-ICV no.2-stepper motor, supply voltage too low
blue SIC 334145.01 E-ICV no.2-stepper motor, supply voltage very low
blue SIC 334146.00 E-ICV no.2-stepper motor, supply voltage too high
blue SIC 334147.14 E-ICV no.2-stepper motor, no connection to controller
blue SIC 334148.14 E-ICV no.2-stepper motor, coil temperature too low
blue SIC 334149.14 E-ICV no.2-stepper motor, coil temperature too high
blue SIC 334152.18 E-ICV no.3-stepper motor, supply voltage too low
blue SIC 334153.01 E-ICV no.3-stepper motor, supply voltage very low
blue SIC 334154.00 E-ICV no.3-stepper motor, supply voltage too high
blue SIC 334155.14 E-ICV no.3-stepper motor, no connection to controller
blue SIC 334156.14 E-ICV no.3-stepper motor, coil temperature too low
blue SIC 334157.14 E-ICV no.3-stepper motor, coil temperature too high
blue SIC 334201.14 E-ICV no.1, stepper motor does not start
blue SIC 334202.14 E-ICV no.2, stepper motor does not start
blue SIC 334203.14 E-ICV no.3, stepper motor does not start
blue SIC 334221.14 E-ICV no.1, stepper motor does not respond to command from controller
blue SIC 334222.14 E-ICV no.2, stepper motor does not respond to command from controller
blue SIC 334223.14 E-ICV no.3, stepper motor does not respond to command from controller
blue SIC 334240.14 Control unit connected to wrong harness connector

 

OU12401,00010AB -19-28APR04-1/1