Hydraulic system fails to function
|
Not enough oil in the system
|
Correct oil level.
|
|
|
Open electrical circuit
|
Check fuses.
|
|
Filter plugged/by-passed warning is active
|
Filter plugged
|
Replace filter.
|
|
Hydraulic oil overheats
|
Cooling system overloaded
|
Dirty oil cooler. Coolant level too low.
|
|
|
Selective control valve accidentally locked in operating position
|
Move selective control valve to neutral position.
|
|
Hitch fails to lift load
|
Excessive load on hitch
|
Reduce load.
|
|
Hitch rate-of-drop too slow
|
Rate-of-drop not adjusted properly
|
Adjust rate-of-drop.
|
|
Insufficient sensitivity to load control
|
System regulator in depth control or mixed control position
|
Move system regulator to load control position.
|
|
Excessive sensitivity when attaching implements
|
System regulator in load control position
|
Place system regulator in depth control position.
|
|
Selective control valves not operating
|
Hoses not connected properly
|
Connect hoses properly.
|
|
Remote control cylinder operates too fast or too slow
|
Incorrect setting for rate-of-flow
|
With mechanical SCVs, adjust the flow control valve.
With electronic SCVs, adjust the rate of flow at the CommandCenter.
|