Change Coolant
CAUTION:
Do not open cap (A) of expansion tank before coolant temperature is below boiling point. First loosen the cap to relieve pressure, then remove cap completely.
NOTE:
If COOL-GARD is not used, the drain interval is reduced to 2 years or 2000 hours of operation.
1.
On tractors with cab, turn the heater control as far as it will go to the right.
2.
First loosen cap (A) and then take it off.
3.
Turn connect/disconnect control (B) anti-clockwise as far as it will go.
4.
Place a container under the drains to trap the coolant as it emerges. Open drain plug (C).
As soon as system is empty, close radiator drain plug (C) and fill the system with clean water.
Run the engine until it reaches operating temperature. Shut off engine and drain cooling system.
Close drain plug again and fill the system with clean water.
IMPORTANT:
Never pour cold water or coolant into the hot engine. Always use warm water or wait until engine has cooled down.
Again run engine until it has reached operating temperature. Shut off engine and drain system again.
Close the drain plug and disconnect line (D). Fill the system with the prescribed coolant (see Fuel, Lubricants, Hydraulic Oil and Coolant section) until coolant emerges from line (D). Retighten line (D).
Add coolant up to the max. mark on both tanks.
Start the engine and run it for 5 minutes.
Shut down the engine and add coolant up to the max. mark on both tanks.
|