Using Auxiliary Heaters — If Equipped
CAUTION: Avoid electrical shock or fire. Use 3-wire, heavy duty
electrical cord with 15-amp rating (14 gauge) minimum, suitable for
outdoor use. Always plug electrical cord into 110-volt outlet protected
with ground fault interrupter.
Two Cold Weather Packages are available from your John Deere
Dealer.
Auxiliary Heater Package, including:
-
Engine Coolant Heater
-
Hydraulic Charge Pump Heater
-
Transmission Heater
Premium Cold Weather Package, including:
-
Engine Coolant Heater
-
Hydraulic Charge Pump Heater
-
Transmission Heater
-
Fuel Heater
-
Rear Window Defroster

RXA0062414-UN-10SEP02
A - Plug
B - Test Button
C - Indicator Light
D - Reset Button
IMPORTANT: Ground fault interrupter protects tractor only, and
does not protect electrical wiring supplying power to tractor. Test
all ground fault interrupters before use.
Auxiliary heaters are used to aid starting in cold weather.
At ambient temperature of -15°C (5°F), coolant heating process
requires about 2 hours. Extend heating period if ambient temperature
is lower.
|
|
OU12401,0001374-19-20051103
|
|