Oil Withdrawal with Hydraulic Motor

LX1037211
LX1037211-UN-21OCT05


IMPORTANT: Never regulate the flow rate by means of an external valve. Always use flow control valves (A).

Maximum obtainable oil flow of transmission/hydraulic oil is dependent on the tractor model and the size of the hydraulic pump installed on the tractor.

Pump size

Flow rate

28 cm3 (1.7 cu.in.)

71 l/min (18.8 gpm)

41 cm3 (2.5 cu.in.)

104 l/min (27.5 gpm)

45 cm3 (2.7 cu.in.)

114 l/min (30.1 gpm)

Shut off engine. Connect the hydraulic hose from the hydraulic motor. Comply with the symbols on the couplers.

Start the engine. Move the control lever to lower. To switch off the hydraulic motor, move the control lever to the float position. Shut off the engine and take out the hydraulic hose.

IMPORTANT: Do not move the control lever to the neutral position, as this may result in back-pressure causing damage to the hydraulic motor and hoses.

OU12401,0001AD3-19-20081011