Battery - Checking Specific Gravity

LX1037218-UN-21OCT05
Use an hydrometer to check the specific gravity of the electrolyte
in each battery cell.
A fully charged battery should have a specific gravity reading
of 1.28. Recharge battery if reading drops below 1.20.
NOTE: In tropical regions, the battery is fully charged when
the reading is 1.23.
|
|
OU12401,0001340-19-20051017
|
|