Oil Withdrawal with Hydraulic Motor

IMPORTANT: Never regulate the flow rate by means of an external valve. Always use flow control valves (A).

The maximum rate of transmission/hydraulic oil flow that can be achieved is 109 l/min (28.8 gpm).

Shut off the engine. Connect the hydraulic hose from the hydraulic motor. Comply with the symbols on the couplers.

Start the engine Move the control lever to "lower". To switch off the hydraulic motor, move the control lever to the "float" position. Shut off the engine and take out the hydraulic hose.

IMPORTANT: Do not move the control lever to the "neutral" position, as this may result in back-pressure causing damage to the hydraulic motor and hoses.

LX1037211

OU12401,0001A00 -19-25JUL08-1/1