Selective Control Valves - Connect Hydraulic Hoses

X9811-UN-23AUG88

LX234751-UN-14OCT15

LX234608-UN-24MAR15
(Mechanical) Multi-Function Lever

LX234750-UN-14OCT15
A - SCV Locking Lever
B - Locking Ring, Mechanical Multi-Function Lever
D - Identification Number
E - Retract Coupler
F - Retract Icon
G - Extend Icon
H - Extend Coupler
CAUTION: Escaping fluid under pressure can penetrate the skin
causing serious injury. Avoid the hazard by relieving pressure before
disconnecting the system lines. If an accident occurs,
consult a doctor immediately. Any fluid that penetrates the skin must
be surgically removed within a few hours or gangrene can result.
CAUTION: Avoid personal injury. Before implements are attached,
hydraulic hoses are connected, and to avoid unintentional implement
movement, observe the following: • Shut off the engine.
• Set selective control valve controls to neutral position
and lock them.
IMPORTANT: Hydraulic hoses can fail due to physical damage,
kinks, age, and exposure. Check hoses regularly. Any dirt,
dust, or other foreign material can damage hydraulic system. Thoroughly
clean hydraulic hoses and SCVs before connecting an implement to the
tractor.
IMPORTANT: Steam cleaning or using a high pressure washer in
the area around the SCV connections and electronics may damage equipment.
In the case of high-pressure washers with a pressure of more than
6900 kPa (69 bar) (1000 psi), a min. distance of 200 mm (8 in.) to
the connections has to be maintained.
-
Engage the park lock and shut off the engine.
-
Lock out SCV controls:
-
Bring the SCV control lever into the neutral position and lock
with the levers (A).
-
Bring the (mechanical) multi-function lever1 into the neutral
position and turn the locking ring (B) in a clockwise direction.
-
Clean dust caps. Turn dust caps to the side to expose ports.
-
IMPORTANT: Be sure to correctly connect hydraulic hoses to couplers.
If hose connections are reversed, machine will not respond to system
controls as expected.
|
Assignment of SCVs at rear
|
|
Extend = lower port
|
|
Retract = upper port
|
NOTE: The SCV ports are identified by numbers I to III (D).
Check if symbols (F) or (G) on the ports, indicating cylinder
movement, match cylinder travel direction.
-
If a single-acting cylinder is connected to an SCV, connect
hose into the bottom part of extend coupler (H). If double-acting
cylinders are used extend coupler (H) is located at the bottom and
retract coupler (E) is located at the top.
-
Push hose(s) firmly into the coupler(s).
NOTE: SCVs are color-coded for easier identification. Hose identification
kits are available from your John Deere™ dealer.
|
SCV Coding
|
|
Selective Control Valve
|
Color
|
|
I
|
Green
|
|
II
|
Blue
|
|
III
|
Brown
|
|
1 If equipped
|