Selective Control Valves, Electronic - Neutral Position

LX1057295
LX1057295-UN-19SEP13

A - Extend (Click Position)

B - Neutral Position

C - Retract (Click Position)

D - Float Position (Detent)

Neutral position (B) allows flow to continue until flow time expires. If no flow time is commanded, then both extend and retract valves turn off.

NOTE: SCV lever should be in neutral position at tractor startup.

Levers in extend or retract positions automatically return to neutral when released. Float position remains detented.

Any position other than neutral or float are ignored until lever is cycled to neutral after engine startup.

OULXA64,0003102-19-20141030