Selective Control Valves, Electronic - Retract and Retract Click Position

Retract

LX1057295
LX1057295-UN-19SEP13

A - Extend (Click Position)

B - Neutral Position

C - Retract (Click Position)

D - Float Position (Detent)

If the lever is moved between neutral (B) and retract click position (C), the cylinder retracts slowly. The further the lever is moved towards click position (C), the faster the hydraulic cylinder retracts. If the lever is released, the lever returns to neutral and the hydraulic cylinder is held in position.

NOTE: Flow time setting is ignored in retract position.

Retract Click Position

Move lever to retract click position (C) and release it; the lever returns to neutral and the hydraulic cylinder retracts in accordance with its preset flow time and preselected flow rate.

The flow rate setting at the SCV page remains in force.

Flow time of the flow rate starts when the lever is moved to the click position. Flow time should be adjusted so cylinder will be fully retracted when time has elapsed.

NOTE: If lever is not returned from the click position to neutral in less than 0.8 seconds, the settings associated with the click position are canceled.

The settings associated with the click position can be canceled by moving the lever out of neutral.

OULXA64,0003104-19-20141030