Selective Control Valves, Electronic - Retract and Retract Click
Position
Retract

LX1057295-UN-19SEP13
A - Extend (Click Position)
B - Neutral Position
C - Retract (Click Position)
D - Float Position (Detent)
If the lever is moved between neutral (B) and retract click
position (C), the cylinder retracts slowly. The further the lever
is moved towards click position (C), the faster the hydraulic cylinder
retracts. If the lever is released, the lever returns to neutral and
the hydraulic cylinder is held in position.
NOTE: Flow time setting is ignored in retract position.
Retract Click Position
Move lever to retract click position (C) and release it; the
lever returns to neutral and the hydraulic cylinder retracts in accordance
with its preset flow time and preselected flow rate.
The flow rate setting at the SCV page remains in force.
Flow time of the flow rate starts when the lever is moved to
the click position. Flow time should be adjusted so cylinder will
be fully retracted when time has elapsed.
NOTE: If lever is not returned from the click position to neutral
in less than 0.8 seconds, the settings associated with the click position
are canceled.
The settings associated with the click position can be canceled
by moving the lever out of neutral.
|
|
OULXA64,0003104-19-20141030
|
|