AutoPowr™/IVT™ — Using Creeper Mode
Creeper mode is entered automatically when a set speed of less
than 2 km/h (1 mph) is selected in speed band 1.
Default ratio between speed bands 1 and 2 is 1:2.5 in creeper
mode. This is done to eliminate rapid acceleration when switch is
moved into speed band 2. If speed band 1 is set at 100 meters per
hour (328.1 feet per hour) for example, the corresponding maximum
speed in band 2 is 250 meters per hour (820.2 feet per hour). The
default ratio may be temporarily overridden (such as when making headland
turns) by increasing speed band 2 to a maximum of 10 km/h (6 mph).
Moving the lever back to band 1 restores the previous working speeds.
Creeper mode is exited when Set Speed 1 is adjusted above 2
km/h (1 mph) or Set Speed 2 is adjusted above 10 km/h (6 mph).
In creeper mode, reverse set speed can be set to no more than
forward set speed. The reverse set speed limit can be temporarily
overridden by moving the Right Hand Reverse Drive Lever into Reverse
Speed Band and increasing the reverse set speed. Moving the Right
Hand Reverse Lever from Reverse Speed Band to Forward Speed Band 1
and not changing Forward Set Speed 1 will reset Reverse Set Speed
to no more than Forward Set Speed.
|
|
OULXA64,0003118-19-20130924
|
|