Selective Control Valves - Disconnect Hydraulic Hoses

LX266990-UN-10OCT16

LX234582-UN-19MAR15

LX234608-UN-24MAR15

LX234609-UN-24MAR15

LX234610-UN-24MAR15
A - SCV Locking Lever
B - Locking Ring, Mechanical Multi-Function Lever
C - Lock Button, Electronic Multi-Function Lever
D - Identification Number
E - Retract Coupler
F - Retract Icon
G - Extend Icon
H - Extend Coupler
CAUTION: Avoid personal injury. Before implements are detached,
hydraulic hoses are disconnected, and to avoid unintentional implement
movement, observe the following: • Lower implements
to the ground.
• Set selective control valve controls to neutral position
and lock them.
-
Lower implement to ground.
-
With the ignition on or with the engine running, bring the selective
control valves briefly into the "Extend" and "Retract" positions.
-
Lock out SCV controls:
-
Bring the SCV control lever into the neutral position and lock
with the levers (A).
-
Turn locking ring (B) to the right to lock the multi-function
lever (mechanical)1.
-
Press lock button (C) for multi-function lever (electrical)1.
-
Switch off the engine and engage the park lock.
-
IMPORTANT: Forcing or jerking SCV hoses when disconnecting can
damage hose ends and SCV couplers.
Pull hoses straight out from couplers.
-
Install dust caps on couplers and tighten them.
|
1 If equipped
|
OULXA64,0003626-19-20170117
|
|