Hydraulic cylinder does not lift load
Move SCV control levers
Excessive load
Reduce load
Hoses not correctly connected
Attach hoses correctly
Wrong hydraulic cylinder size
Use correct cylinder size
SCV lock button active
Deactivate SCV lock button
Incorrect or damaged hose connections
Replace hose connections
Hydraulic cylinder extends too fast or too slow
Adjust flow rate
Hydraulic cylinder works the wrong way around
Reverse hose connections
Hoses cannot be connected
Replace connectors with ISO Standard connectors
Detent time of the SCV does not hold correctly or releases too early
Set detent time correctly
Control lever of SCV is not released in the neutral position
Release SCV valve lever from detent position to neutral position in less than 0.8 seconds
Control lever of the SCV is not released
Do not press the lever down into the float position (detent position)
Lever mechanism failed
Contact your authorized dealer.
Implement does not operate or does not operate correctly
See Operator's Manual of the implement