Selective Control Valves (SCV), Mechanical - Raise Rate

LX1045800-UN-22DEC10
Flow control valves (A) can be used to regulate the rate at
which hydraulic cylinders extend and retract (raise and lower). When
lowering, make sure that the SCV's control lever is NOT moved into
float position.
IMPORTANT: Full extension and retraction of a hydraulic cylinder
should require more than 1,5 seconds. Faster retracting or extending
may cause damage.
|
|
OULXA64,0003621-19-20150317
|
|