Front-Wheel Drive Axle (730, 733 and 735) - Final Drives without
Brakes, Check Oil Level

TS281-UN-15APR13
CAUTION: Danger of injury from hot components or hot, pressurized
oil. Touching hot surfaces, accessories, or hoses and
leads can cause injury.
Avoid contact with hot surfaces or hot oil.
Check oil level when oil is warm (approx. 40 °C; 103 °F).
Unscrew the level screw plug slowly.
NOTE: Replace oil in the final drives after the first 100 and
after the first 1500 hours of operation. Then change after every 1500
hours of operation or once every 2 years, whichever occurs first.
-
Turn the wheel until OIL LEVEL mark
(B) is horizontal.

LX1057460-UN-21AUG14
-
Remove oil level screw plug (A) and put a new O-ring on it.
Oil must be level with drain screw bore.
-
If necessary, top up with oil at this point.
|
Oil to be used
|
Hy-Gard Transmission/Hydraulic Oil. See also Section 200E.
|
-
Put a new O-ring on the level screw plug and tighten it to 90
N·m (66 lb-ft).
|
Hy-Gard is a trademark of Deere & Company
|
OULXA64,4ZYL,000425B-19-20200120
|
|