Operating Headland Management System (HMS)
HMS, differential lock, MFWD (AUTO position), and PTO can be selected singly or together to switch on or off
automatically
when using raise/lower switch (A).
Select differential lock, MFWD, and/or PTO as necessary. Activate the system by pressing HMS switch (B). Indicator lights will flash slowly, with an audible warning.
At the end of the field, push hitch raise/lower switch. The differential lock will stop immediately, the PTO will stop after hitch has raised 10 percent of lift travel, and MFWD will stop when implement reaches maximum height. Indicator lights will flash quickly.
When implement is lowered, the selected function(s) will be activated immediately. Indicator lights will flash slowly. For safety reasons, the PTO must be switched on manually.
To switch off HMS, press HMS switch again. Indicator lights will glow continuosly, with an audible warning.
NOTE:
MFWD can be set for continuous operation at any time, regardless of the HMS mode. Move MFWD switch from AUTO position to ON position.
|
A-Raise/Lower Switch
B-HMS Switch
|