Connecting and Disconnecting Hydraulic Hoses

causym CAUTION: Push transport lock touch switch (A) on SCV TouchSet monitor before attaching or detaching implements to prevent implement movement and possible personal injury.

IMPORTANT: Hydraulic hoses can fail due to physical damage, kinks, age and exposure. Check hoses regularly.

Be sure hose ends are clean prior to use to minimize hydraulic system contamination.

Clean dust covers (B). Turn dust covers upward to expose coupler ports.

NOTE: Remote cylinder couplers are designated "I" through "V". "I" is the bottom coupler.

Check to be sure connection on coupler matches cylinder travel direction required.

When using SCV with single acting cylinders, plug hose into extend side of coupler (D).


A-Transport Lock Touch Switch
B-Dust Covers
C-Retract Side
D-Extend Side

RW26141
RW26575

AG,RF30435,2067 -19-26JUL00-1/2


Move SCV lever to neutral position with no time flow "commanded". Push hose firmly into receptacle.

Before disconnecting cylinder hoses, lower implement to the ground.

NOTE: To relieve hydraulic pressure in implement, move SCV control lever to float position, while engine is running.

Push coupler lever (A) down slightly to relieve any pressure buildup of trapped oil before removing hoses.

Pull hose straight out from receptacle.

RW56116A

AG,RF30435,2067 -19-26JUL00-2/2