Performance Monitor-Wheel Slip
Radar must be operational to provide true ground speed. If true ground speed is not available, "---" will be displayed.
NOTE:
Illustration shows current wheel slip (C) is 4% and alarm setting at 6%. Each bar on the bargraph represents 2% slip.
1.
Press
% SLIP
switch (A). Bargraph and numeric display will show current wheel slip.
2.
Press switch again to display the wheel slip alarm setting. Alarm symbol (E) will be displayed.
NOTE:
Bargraph (C) flashes when wheel slip exceeds alarm limit.
3.
Press
SET/SAVE
switch (B) to change alarm value.
4.
Input alarm setting using touch pad, then press
SET/SAVE
switch again.
NOTE:
Entering "0" as an alarm value will shut off alarm.
Calibration:
Drive tractor 8 km/h (5 mph). Wheels must not be slipping.
Press the
"0" ZERO
switch for 4 seconds. "CAL" will be displayed during calculation.
NOTE:
Err
will flash on display field if calibration was not performed correctly. Repeat calibration procedure.
Display will return to percent slip if calibration was successful.
|