Performance Monitor-Wheel Slip

Radar must be operational to provide true ground speed. If true ground speed is not available, "---" will be displayed.

NOTE: Illustration shows current wheel slip (C) is 4% and alarm setting at 6%. Each bar on the bargraph represents 2% slip.

1. Press % SLIP switch (A). Bargraph and numeric display will show current wheel slip.

2. Press switch again to display the wheel slip alarm setting. Alarm symbol (E) will be displayed.

NOTE: Bargraph (C) flashes when wheel slip exceeds alarm limit.

3. Press SET/SAVE switch (B) to change alarm value.

4. Input alarm setting using touch pad, then press SET/SAVE switch again.

NOTE: Entering "0" as an alarm value will shut off alarm.

Calibration:

Drive tractor 8 km/h (5 mph). Wheels must not be slipping.

Press the "0" ZERO switch for 4 seconds. "CAL" will be displayed during calculation.

NOTE: Err will flash on display field if calibration was not performed correctly. Repeat calibration procedure.

Display will return to percent slip if calibration was successful.

RW26357


A-% SLIP
B-SET/SAVE
C-Bargraph
D-Numeric Display
E-Wheel Slip Alarm

AG,RX15494,2969 -19-11NOV99-1/1