Depth control does not function correctly
|
Transport lock-up valve closed
|
Open valve
|
|
Cylinders not "rephased" (synchronized)
|
"Rephase" (synchronize) cylinders
IMPORTANT:
Be sure all air is bled from depth control system
|
|
Machine operating at different depths
|
Hard ground or adverse operating conditions
See implement operator's manual
|
|
Cylinder leakage
|
Check for leakage
Repair or replace cylinders; see your John Deere Dealer
|
|
Insufficient tractor hydraulic pressure
|
Check tractor hydraulic pressure; use correct size cylinders for tractor pressure
|
|
Hydraulic hoses not connected correctly
|
Reconnect correctly
|