Servicing the Batteries
CAUTION:
Battery gas can explode. Keep sparks and flames away from batteries. Use a flashlight to check battery electrolyte level.
Never check battery charge by placing a metal object across the posts. Use a voltmeter or hydrometer.
Always remove ground cable at frame FIRST and connect it LAST.
| SERVICE INTERVAL - 250 HOURS |
Keep connections (A) and (B) clean and tight. Remove corrosion, and wash terminals with a solution of baking soda and water.
CAUTION:
Avoid contact with poisonous sulfuric acid in battery electrolyte. It is strong enough to burn skin, eat holes in clothing, and cause blindness if splashed into eyes.
Battery posts, terminals, and related accessories contain lead and lead compounds, chemicals known to the state of California to cause cancer and reproductive harm. WASH HANDS AFTER HANDLING.
Check the specific gravity of the electrolyte in each battery cell. Charge batteries if reading is below 1.215.
Check level of electrolyte in each cell (C). If low, fill to bottom of filler necks with CLEAN, SOFT water. DO NOT OVERFILL.
IMPORTANT:
Do not add water in freezing weather unless tractor will be operated at least 30 minutes.
Coat terminals with small amount of grease and replace terminal shields.
|