Setting PTO Engagement Acceleration (Rear PTO - Standard, Front PTO - If Equipped)

Menu Items on Display (D)

RXA0082348


A-Settings Switch


B-Command Dial


C-Select Switch


D-Display

NOTE: Not all languages are displayed on CommandCenter. Reference "Selecting Units and Language" in this section for more information on languages that can be displayed.

NOTE: RPTO Engage will appear on all tractors. FPTO Engage will only appear if tractor is equipped with optional front PTO.

Press Settings Switch (A) to view menu items on Display (D). Rotate Command Dial (B) to select RPTO Engage and press Select Switch (C).

RPTO Engage Auto
  Low Rate
  High Rate

 

Using Command Dial, select Auto, Low Rate or High Rate engagement acceleration and press Select Switch.

Auto setting is used for most implements, and is the factory setting in the CommandCenter. This setting

provides software logic to determine the engagement rate for the PTO clutch, based on PTO speed sensor feedback. If the PTO does not turn fast enough during initial PTO clutch engagement, the engagement rate is automatically increased to avoid clutch slip and PTO shutdown.

IMPORTANT: If operator is experiencing problems with PTO clutch engagement in Auto setting, and Code CCU 001883.01 (Rear PTO Underspeed) or PTF 001882.01 (Front PTO Underspeed) is displayed, change PTO engagement setting in CommandCenter from Auto to High Rate to prevent drive train damage.

Low Rate can be used where gradual PTO startup is required, or if Auto engagement is too aggressive or inconsistent.

High Rate can be used for applications where PTO clutch engagement needs to be unusually aggressive.

OURX986,00002B8 -19-28JUL05-1/1