Removing Tractor From Storage

Perform the following steps to remove tractor from storage:

  • Remove all coverings in cab
  • Unseal all openings sealed during storage
  • Install alternator, fan, and compressor belt
  • Check all fluid levels
  • Fill the fuel tank
  • Check tire inflation pressures
  • Install batteries and connect cables
  • Perform all 10 Hour, 250 Hour, and 750 Hour services as required
  • Check all instruments and indicators by turning key to the ON position
  • Disconnect fuel shut-off solenoid and crank the engine a few revolutions

    IMPORTANT: DO NOT operate the starter for more than 30 seconds. Wait at least two

    minutes for starter to cool before trying again.

  • Connect fuel shut-off solenoid and start engine
  • Operate engine at slow idle for several minutes

    IMPORTANT: If air conditioning compressor is locked up, engine operation with compressor clutch engaged will damage belt or compressor.

  • Check air conditioning
  • Check all other system functions
  • Warm up tractor before putting tractor under load

AG,RX15494,1913 -19-06SEP99-1/1