Adjusting Timed Detent

RW26052
 

A-SCV Switch

B-Display

C-Knob

 

Timed Detent Function:

Three selected timed detents are available to hold each SCV function for an adjustable time.

  • 0 (No Timed Detent)-hold control lever in extend or retract position. Oil flow continues until control lever is released. (This position is recommended for implements requiring frequent height or depth adjustments.)
  • 1-19 Seconds (Adjustable Timed Detent)-control lever is moved to full (detented) extend or retract position and released. Lever returns to neutral. Oil flow continues until time selected expires. (This position is recommended for implements operating at full depth or with depth stops on the cylinders.)
  • C (Continuous Flow)-control lever is moved to full (detented) extend or retract position and released. Lever returns to Neutral. Oil flow continues until control lever is moved away from Neutral or until tractor is shut off. (This position is recommended for
    hydraulic motor use or applications where a continuous flow of oil is required.)

Timed Detent Adjustment:

Press selected SCV switch (A). Display below touch switch shows set time.

Adjust displayed timed detent by turning knob (C) clockwise (longer detent time or "C" continuous detent time). Turn knob counterclockwise (shorter detent time or "0" zero detent time). Time setting is shown on display (B).

Settings will take effect immediately. SCV can be operated to observe detents while in adjust mode.

NOTE: Move SCV lever slightly forward or rearward from neutral to cancel a detent function manually.

OURX984,0000082 -19-17OCT02-1/1