SCV Lever-Retract Detent Position
Push desired lever or levers forward to "click" detent position and release. Lever will return to neutral position, but flow will continue at rate set on SCV TouchSet panel with SCV flow rate and flow time knobs (as last set for corresponding SCV). (See ADJUSTING SELECTIVE CONTROL VALVES FLOW RATE and ADJUSTING TIMED DETENT, in this Section.)
Flow timing will start when SCV lever is first moved into detent but not before. Oil flow will start as soon as SCV lever is moved but will not reach preset rate until just before lever is moved to detent position. SCV flow time should be adjusted so cylinder will be fully retracted when time has elapsed.
Detent can be cancelled by moving SCV lever slightly forward or rearward from neutral after lever has returned to neutral or by holding lever in retract position for more than 0.8 seconds after lever is released from detent.
Moving lever quickly from neutral to float position will cause continuous operation and allow motor to turn freely.
NOTE:
Detent positions ignored at startup until lever is cycled to neutral.
|