Service Hours
Press service hours switch (F) to display operating hours since tractor was last serviced. Display will show current service hours and service book symbol will flash when operating hours since last service exceeds interval set point.
NOTE:
The service hour set point can be changed. See your John Deere Dealer.
Default service interval set point is 250 hours. Press switch (F) for 3 seconds to reset to zero after scheduled service.
Service Code
Press code switch (G) to display code for current active alarm, if any. Press switch to display electronic controller and code number. Record controller and code number for future reference.
Check code displayed with codes listed in Service Codes Section to find possible solution for problem listed beside service code. If code displayed requires a service technician, identifying the possible problem by using the code number will help arrive at a quicker solution.
NOTE:
Alarms can be suppressed, for the duration of the operation, by pressing the code switch for 7 seconds. The alarm will reappear the next time the tractor is started, if the problem still exists.
Distance Traveled
NOTE:
Radar is required for accurate readings to adjust for traction slippage.
|
Press distance switch (H) to display distance in feet (meters) since tractor was started or distance traveled was reset. Reset to zero by pressing switch for three seconds.
Engine Coolant Temperature
Hold switches (B) and (G) simultaneously to display current engine coolant temperature in degrees Fahrenheit. Pushing them a second time toggles them back to degrees Celsius. They continue to toggle back and forth with each subsequent push.
Hydraulic Oil Temperature
Hold switches (C) and (F) simultaneously to display current hydraulic oil temperature in degrees Fahrenheit. Pushing them a second time toggles them back to degrees Celsius. They continue to toggle back and forth with each subsequent push.
Display Light Intensity
Night-time light intensity for all displays can be adjusted when the light switch is in the "ON" position.
Pressing switches (E) and (F) simultaneously on panel will INCREASE the light intensity. Pressing switches (G) and (H) simultaneously will DECREASE the intensity.
NOTE:
Key switch must be left ON for 30 seconds to save new setting.
|