SCV Lever-Extend Detent Position
Pull desired lever or levers rearward to "click" detent position and release. Lever will return to neutral position, but flow will continue at rate set on SCV TouchSet panel with SCV flow rate and flow time knobs (as last set for corresponding SCV). (See ADJUSTING SELECTIVE CONTROL VALVE FLOW RATE and ADJUSTING DETENT TIME, in this Section.)
Flow timing will start when SCV lever is first moved into detent but not before. Oil flow will start as soon as SCV lever is moved but will not reach preset rate until just before lever is moved to detent position. SCV flow time should be adjusted so cylinder will be fully extended when time has elapsed.
Detent can be cancelled by moving SCV lever slightly forward or rearward from neutral after lever has returned to neutral or by holding lever in extend position for more than 0.8 seconds after lever is released from detent.
NOTE:
Detent positions ignored at startup until lever is cycled to neutral.
|