3.
Remove thermostat cover (A) and thermostats. Install cover without thermostats. Tighten cap screws.
IMPORTANT:
Remove thermostats and operate cab heater during flushing procedure.
4.
Close drain cocks and fill system with a
commercial cooling system cleaning solution
. Operate engine to normal temperature. Stop engine and drain system.
IMPORTANT:
Never pour cold water or coolant into hot engine. Use warm water or wait until engine has cooled.
5.
Close drain cocks and fill system with
clean water
. Operate engine to normal temperature. Stop engine and drain system.
NOTE:
Vent notch of upper thermostat should be at the top when installing.
6.
Remove thermostat cover and clean sealing area. Apply sealant to new gasket and install thermostats and gasket. Tighten cap screws to 48 N·m (35 lb-ft).
7.
Close drain cocks again. Fill system with the
specified coolant
. Operate engine to circulate and mix coolant. Coolant level should be up to mark on expansion tank.
|