Operator Enclosure Troubleshooting

Symptom Problem Solution

Blower not keeping dust out of operator enclosure

Defective seal around filter

Check seal condition

Check filter for correct installation

Defective filter

Replace filter

Excessive air leak

Seal air leaks

Blower air flow too low

See Blower Air Flow Too Low

Blower air flow too low

Clogged filter or air intake screen

Clean

Heater core or evaporator core clogged

Clean

Heater will not shut off

Heater hoses connected incorrectly

See your John Deere Dealer

Air conditioner not cooling

Low voltage

Check charging circuit. (See Checking Air Conditioning System in the General Maintenance and Inspection Section)

Low refrigerant

Check sight glass. (See Checking Air Conditioning System in the General Maintenance and Inspection Section

Belt slipping

Check belt tension

Heater switched on

Switch heater off

Compressor stuck

Rock compressor pulley back and forth

Intermittent cooling

Air restriction

Clean side screens, radiator and oil cooler condenser. (See Checking Air Conditioning System in the General Maintenance and Inspection Section)

Seat suspension not working

Blown fuse

Replace fuse

Radio does not function

Blown fuse

Replace fuse

RX15494,0000154 -19-06NOV01-1/1