Automatic Temperature Control (ATC) Diagnostic Trouble Codes - ClimaTrak

IMPORTANT: Check the cleanliness of the condenser at the front of the tractor and make sure the cab recirculation air filter is not plugged for all ATC diagnostic trouble codes. If the codes return, contact your John Deere dealer as soon as possible.

Automatic Temperature Control (ATC) Diagnostic Trouble Codes - ClimaTrak
Diagnostic Trouble Code Display Solution
ATC 000170.03 Cab Temperature Sensor Circuit Voltage High Cab Temperature Sensor circuit voltage too high.
ATC 000170.04 Cab Temperature Sensor Circuit Voltage Low Cab Temperature Sensor circuit voltage too low.
ATC 000171.03 Ambient Temperature Sensor Circuit Voltage High Ambient temperature sensor circuit voltage too high.
ATC 000171.04 Ambient Temperature Sensor Circuit Voltage Low Ambient temperature sensor circuit voltage too low.
ATC 000628.12 ATC Programming In process of updating software
ATC 000630.02 ATC Calibration Fault/Data Invalid Automatic Temperature Control Unit (ATC) invalid calibration values or failure of calibration memory
ATC 000639.14 ATC CAN Error Exceeded Too many errors received by Automatic Temperature Control Unit (ATC).
ATC 000871.03 Refrigerant Pressure Sensor Circuit Voltage High Refrigerant Pressure Sensor circuit voltage too high.
ATC 000871.04 Refrigerant Pressure Sensor Circuit Voltage Low Refrigerant Pressure Sensor circuit voltage too low.
ATC 000871.13 Refrigerant Pressure Sensor Not Calibrated Refrigerant pressure sensor out of range.
ATC 000876.10 Excessive A/C Clutch Cycling A/C Compressor Clutch cycling more than 6 times per minute
ATC 000876.14 Compressor Shutoff Due to Engine Overheat A/C Compressor Clutch turned off by Automatic Temperature Control Unit (ATC) due to overheated engine.
ATC 000923.03 Circulation Blower Motor Circuit Voltage High Circuit voltage between the Circulation Blower Motor and the Blower Motor Driver too high.
ATC 000923.04 Circulation Blower Motor Circuit Voltage Low Circuit voltage between the Circulation Blower Motor and the Blower Motor Driver too low.
ATC 000923.12 Circulation Blower Motor Driver Circuit Fault Circuit failure in the Circulation Blower Motor Driver
ATC 001079.03 ATC Sensor Supply Voltage High Automatic Temperature Control Unit (ATC) sensor supply voltage above 5.0 volts
ATC 001079.04 ATC Sensor Supply Voltage Low Automatic Temperature Control Unit (ATC) sensor supply voltage below 0.5 volts
ATC 001546.03 Water Valve Position Sensor Circuit Voltage High A/C Water Valve Position Sensor circuit voltage too high.

 

OURX935,0000094 -19-25FEB08-1/3


Automatic Temperature Control (ATC) Diagnostic Trouble Codes - ClimaTrak
Diagnostic Trouble Code Display Solution
ATC 001546.04 Water Valve Position Sensor Circuit Voltage Low A/C Water Valve Position Sensor circuit voltage too low.
ATC 001547.03 Evaporator Temperature Sensor Circuit Voltage High Evaporator Temperature Sensor circuit voltage too high
ATC 001547.04 Evaporator Temperature Sensor Circuit Voltage Low Evaporator Temperature Sensor circuit voltage too low.
ATC 001548.03 Outlet Air Temperature Sensor Circuit Voltage High Outlet Air Temperature Sensor circuit voltage too low.
ATC 001548.04 Outlet Air Temperature Sensor Circuit Voltage Low Outlet Air Temperature Sensor circuit voltage too low.
ATC 001549.03 Water Valve Motor Circuit Voltage High Water Valve Motor circuit voltage too high.
ATC 001549.04 Water Valve Motor Circuit Voltage Low Water Valve Motor circuit voltage too low.
ATC 001549.07 Water Valve Motor Mechanical Fault Mechanical failure in the Water Valve Motor
ATC 001549.13 Water Valve Motor Not Calibrated Water Valve not being calibrated after being replaced
ATC 001551.03 Pressurizer Blower Motor Circuit Voltage High A/C Pressurizer Blower Motor circuit voltage too high.
ATC 001551.04 Pressurizer Blower Motor Circuit Voltage Low A/C Pressurizer Blower Motor circuit voltage too low.
ATC 001552.03 Cab Temperature Control Circuit Voltage High Cab Temperature Control circuit voltage too high.
ATC 001552.03 Cab Temperature Control Circuit Voltage High Cab Temperature Control circuit voltage too high.
ATC 001552.04 Cab Temperature Control Circuit Voltage Low A/C Cab Temperature Control circuit voltage too low.
ATC 001553.03 Blower Control Circuit Voltage High A/C Blower Control circuit voltage too high.
ATC 001553.04 Blower Control Circuit Voltage Low Blower Control Circuit Voltage Low
ATC 002000.09 ECU Message Missing Automatic Temperature Control Unit (ATC) not receiving required messages from the ECU
ATC 523848.03 Air Flow Mode Motor Circuit Voltage High A/C Air Flow Mode Motor circuit voltage too high.
ATC 523848.04 Air Flow Mode Motor Circuit Voltage Low A/C Air Flow Mode Motor circuit voltage too low.
ATC 523848.05 Air Flow Mode Motor Circuit Current Low A/C Air Flow Mode Motor current is too low.
ATC 523848.06 Air Flow Mode Motor Circuit Current High A/C Air Flow Mode Motor current is too high
ATC 523848.07 Air Flow Mode Motor Mechanical Fault Mechanical failure in the Air Flow Mode Motor

 

OURX935,0000094 -19-25FEB08-2/3


Automatic Temperature Control (ATC) Diagnostic Trouble Codes - ClimaTrak
Diagnostic Trouble Code Display Solution
ATC 523848.13 Air Flow Mode Motor Not Calibrated Invalid calibration, or calibration not being performed on the Air Flow Mode Motor
ATC 524202.03 Ambient Temperature Sensor Circuit Voltage High Ambient temperature sensor circuit voltage too high.
ATC524202.04 Ambient Temperature Sensor Circuit Voltage Low Ambient temperature sensor circuit voltage too low.

 

OURX935,0000094 -19-25FEB08-3/3