Cleaning Hydraulic Oil Suction Screen

SERVICE INTERVAL - 1500 HOURS
 

 

Drain transmission/hydraulic oil.

Remove cap screws (A) and tube on differential case front left side. Remove suction screen (B) and wash carefully in solvent, then blow dry screen with compressed air.

Install tube (C) making sure O-ring (D) is correctly positioned.


A-Cap Screws
B-Suction Screen
C-Tube
D-O-Ring

RXA0082965

OURX935,0000444 -19-08JAN08-1/1