Drain Intervals for Diesel Engine Coolant
Drain and flush the cooling system and refill with fresh coolant
at the indicated interval, which varies with the coolant used.
John Deere COOL-GARD™ II Premix, COOL-GARD II PG Premix,
and COOL-GARD II Concentrate are maintenance free coolants for up
to 6 years or 6000 hours of operation, provided that the cooling system
is topped off using only John Deere COOL-GARD II Premix or COOL-GARD
II PG Premix.
Test the coolant condition annually with Coolant Test Strips
designed for use with John Deere COOL-GARD II coolants. If the test
strip chart indicates that additive is required, add John Deere COOL-GARD
II Coolant Extender as directed.
If John Deere COOL-GARD™ II Premix, COOL-GARD II PG Premix,
or COOL-GARD II Concentrate is used, but the coolant is not tested
OR additives are not replenished by adding John Deere COOL-GARD II
Coolant Extender, the drain interval is 4 years or 4000 hours of operation.
This drain interval only applies to COOL-GARD II coolants that have
been maintained within a 40% to 60% mixture of concentrate with quality
water.
If a coolant other than COOL-GARD II or COOL-GARD II PG is
used, reduce the drain interval to 2 years or 2000 hours of operation.
|
|
OURX935,00000E8-19-20101019
|
|