John Deere Break-In™ Plus Engine Oil
To confirm which engine your tractor is equipped
with, See Section 145 Record Engine Serial Number in this Operator's
Manual.
Initial Service Intervals
The initial break-in service interval of a new or rebuilt wet
sleeve engine with Break-In Plus must go at least 100 hours to assure
the surface mating of the rings and liners has had an opportunity
to occur. The 100 hour minimum applies to all new or rebuilt engines.
The maximum service interval is the same as the service interval recommendations
for Plus-50 II.
New engines are filled at the factory with John Deere Break-In
Plus™ Engine Oil. During the break-in period, add John Deere
Break-In Plus Engine Oil as needed to maintain the specified oil level.
Operate the engine under various conditions, particularly heavy
loads with minimal idling, to help seat engine components properly.
If John Deere Break-In Plus Engine Oil is not available, use
an SAE 10W-30 viscosity grade diesel engine oil meeting one of the
following:
-
API Service Category CJ-4
-
ACEA Oil Sequence E9
-
ACEA Oil Sequence E6
If one of these oils is used during the initial operation of
a new or rebuilt engine, change the oil and filter between a minimum
of 100 hours and a maximum of 250 hours.
IMPORTANT: Do not use any other engine oils during the initial
break-in of a new or rebuilt engine.
John Deere Break-In Plus Engine Oil can be used for all John
Deere diesel engines at all emission certification levels.
After the break-in period, use John Deere Plus-50™ II
or other diesel engine oil as recommended in this manual
|
|
OURX935,0000182-19-20101126
|
|