Remote cylinder will not lift load
Cycle SCV levers
Excessive load
Reduce load
Hoses not completely installed
Attach hoses correctly
Incorrect remote cylinder size
Use correct size cylinder
SCV transport lock engaged
Release SCV transport lock
Incorrect or damaged hose tips
Replace hose tips
Remote cylinder rate of travel too fast or too slow
Adjust flow rate
Direction of remote cylinder travel is reversed
Reverse hose connections
Hoses will not couple
Replace connectors with ISO Standard connectors
Detent does not hold or releases too soon
Set time correctly
SCV lever is not being released to neutral
Release SCV lever from detent to neutral in less than 0.8 seconds
SCV lever does not release
Do not push lever down in forward position
Lever mechanism failed
See your John Deere Dealer
Implement does not operate or does not operate correctly
See implement operator's manual
See your John Deere Dealer
Implement is sluggish
Replace SCV stack filter
OURX935,0000655-19-20090912