Using a Battery Booster or Charger

RXA0086722-UN-10FEB06

RXA0099988-UN-12DEC08
A - Positive Terminal
B - Ground
CAUTION: Gas given off by batteries is explosive. Keep sparks
and flames away from batteries. Make last connection and first disconnection
at a point away from booster batteries.
IMPORTANT: Be sure polarity is correct before making connections.
Reversed polarity will damage electrical system or possibly cause
battery to explode. If two or more booster batteries
are used, they must be connected in parallel ensuring booster batteries
are producing a 12 volt charge.
Avoid possible injury or death from machinery runaway.
Do not start engine by shorting across starter terminals. Machine
will start in gear if normal circuitry is bypassed.
NEVER start engine while standing on ground. Start engine only
from operator’s seat, with transmission in neutral or park.
Booster Battery
-
Attach cable (red) to the remote positive terminal (A) of the
starter and positive terminal of booster battery.
-
Attach (black) battery cable to negative terminal of booster
battery. Attach other end to a ground (B) on tractor frame.
-
Remove ground cable first when disconnecting.
Battery Charger
-
IMPORTANT: Set battery charger at the nominal 12 volt and no
more than 16 volt maximum.
Attach positive charger lead to positive remote terminal with
charger in OFF position. Attach negative charger lead to negative
ground at tractor frame, away from batteries.
-
Switch charger to ON and charge battery according to charger
manufacturers instructions.
-
Switch charger to OFF. Remove negative charger lead first, then
positive lead.
|
|
OURX935,0000708-19-20081218
|
|