Break-In Check-After First 100 Hours

IMPORTANT: Refill with John Deere Break-in Oil for an additional 100 hours, if tractor is used under light load conditions during first 100 hours.

  • Change engine oil and filter
  • Change fuel pre-filter
  • Change transmission/axle filters
  • Change hydraulic oil filter
  • Inspect and clean hydraulic oil reservoir screen

NOTE: Reset service hours to zero after service.

RW29387,0000253 -19-07OCT08-1/1