Replacing Hydraulic Reservoir Breather Filter

SERVICE INTERVAL - 750 HOURS

 

IMPORTANT: Verify direction (see arrow on filter) of air flow before removing breather filter. Install new filter in same direction as one removed. Improper installation of filter could cause hydraulic system damage.

1. Verify direction of arrow on filter and remove filter from line.

2. Replace new filter in same direction as one removed.

RXA0086711


A-Breather Filter

RW29387,000038D -19-25OCT06-1/1