Replacing Hydraulic Reservoir Breather Filter
| SERVICE INTERVAL - 750 HOURS |
IMPORTANT:
Verify direction (see arrow on filter) of air flow before removing breather filter. Install new filter in same direction as one removed. Improper installation of filter could cause hydraulic system damage.
1.
Verify direction of arrow on filter and remove filter from line.
2.
Replace new filter in same direction as one removed.
|