Every 25 hours
Wipe grease fittings clean before lubricating. If grease fitting
is missing, replace immediately.
-
Lubricate the following with grease:
-
Topper Assembly — 6 Fittings
-
Crop Dividers — 10 Fittings (18 opt)
-
Front Lift Cylinders: Track — 6 Fittings
-
Height Indicator Assembly: Wheels — 2 Fittings
-
Elevator Swing Table — 9 Fittings
-
Primary Extractor Fan— 5 Fittings
-
Secondary Extractor Fan — 3 Fittings
-
Feed Roller Cradle Pins — 10 Fittings
-
Elevator Cable Support Sheave — 2 Fittings
-
Crop Divider Tilting Cylinder Pins — 4 Fittings
-
Height Indicator Rocker Arm Assembly — 2 Fittings
-
Adjustable knockdown roller— 2Fittings
-
Clean out the following with compressed air:
IMPORTANT: In dusty conditions, check daily.
-
Cab Air Filter
-
Cab Pre-Cleaner
-
Engine Compartment
-
Radiator
-
Oil Cooler
-
Charge Air Cooler
-
AC Condenser
-
AC Recirculation Filter
NOTE: When using compressed air to clean out components, blow
air opposite the normal direction of airflow. Blowing air in the direction
of normal airflow can force debris further into a component, clogging
it more.
-
Check the oil levels in the following components:
-
Basecutter gear box
-
Chopper gear box
NOTE: Fill to top of site glass.
-
Clean harvester of excess mud and leaf trash, especially feed
rollers.
|
|
GB52027,0000583-19-20090519
|
|