Checking Crankcase Vent Hose and Valve

RG13818
RG13818-UN-11JAN05

Clean Crankcase Vent Tube

A - Vent Tube


  1. Loosen clamp on crankcase vent hose (A).

  2. Remove crankcase vent valve (not shown) from rocker arm cover.

  3. Remove valve from crankcase vent hose and clean hose. Ensure hose is not plugged.

  4. Shake crankcase valve. If free movement of valve is heard while shaking, valve can be reused. Replace valve if rattle is not heard.

  5. Install the valve and vent hose. Attach valve to bracket with two screws provided. Tighten hose clamp securely.

JG50163,000028B-19-20120413