Checking Crankcase Vent Hose and Valve

RG13818-UN-11JAN05
Clean Crankcase Vent Tube
A - Vent Tube
-
Loosen clamp on crankcase vent hose (A).
-
Remove crankcase vent valve (not shown) from rocker arm cover.
-
Remove valve from crankcase vent hose and clean hose. Ensure
hose is not plugged.
-
Shake crankcase valve. If free movement of valve is heard while
shaking, valve can be reused. Replace valve if rattle is not heard.
-
Install the valve and vent hose. Attach valve to bracket with
two screws provided. Tighten hose clamp securely.
|
|
JG50163,000028B-19-20120413
|
|