Using Battery Charger

Specific Gravity to 27°C (80°F)

Load Status

Open Circuit Voltage

1.260-1.280

100%

12,6 +

1.230-1.250

75%

12,4

1.200-1.220

50%

12,2

1.179-1.190

25%

12,0

1.110-1.130

Discharged

11,7

A battery charger may be used as a booster to start engine.

Do not use battery charger as a booster if a battery has a specific gravity below 1.150.

Disconnect battery ground before you charge batteries in the machine to prevent damage to electrical components.