Inspect Filter

RW4768-UN-15DEC88
Air restriction indicator will not signal correctly if an filter
has a break or is not correctly sealed in air cleaner housing. Throw
away filter that has even the slightest damage. If gasket is broken
or missing, install a new element.
-
Hold a bright light (A) inside filter and check carefully for
holes. Discard any filter that has even the slightest hole.
-
Be sure outer screen (B) is not dented. Vibration would quickly
wear a hole in filter.
-
Be sure filter gasket (C) is in good condition. Press the gasket
on the new filter to see if it springs back. Make sure the new filter
has a highly compressible gasket that springs back when finger pressure
is released. If gasket is damaged or missing, replace filter.
|
|
T803324,000056F-19-20050210
|
|