Switching ON Control Monitor in Diagnostic Mode (Baler without Precutter Device)

The diagnostic mode allows the operator to check all electrical components which are connected to the monitor.

Access To Diagnostic Mode

causym CAUTION: DO NOT TAKE CHANCES! To avoid severe injuries or death while servicing or adjusting baler electrical components:

1. Disengage PTO.
2. Shut off engine and remove the key.
3. Do not allow anyone to use the monitor while servicing or adjusting electrical components on baler.

IMPORTANT: Do not operate the monitor in diagnostic mode for baling.

Enter the diagnostic mode as follows:

Press and hold DEERE key while switching ON the monitor in twine or net mode position depending on the test which must be performed.

Keep on holding DEERE key until monitor LCD screen displays the following info:

At first, the wrapping mode pictogram (A) chosen and the baler model on digits (B).

Then, if equipped with the sensor, LCD screen will display the lower belt drive roll rotating speed when PTO is engaged. See "Baler Roll Numbering" in the "Service" Section.

The displayed value on the LCD screen should be:

1. Gear box position 540 rpm:

Specification

PTO 540 rpm -Speed 310 rpm
PTO 1000 rpm -Speed Not allowed

CC001211

AG,OUCC006,518 -19-01SEP00-1/2


2. Gear box position 1000 rpm:

Specification

PTO 540 rpm -Speed 169 rpm
PTO 1000 rpm -Speed 314 rpm

Switch OFF monitor to leave the diagnostic mode.

AG,OUCC006,518 -19-01SEP00-2/2