Adjusting Bale Size Switch (Baler with Electronic Wrapping Control Monitor)

Close the gate, then loosen switch mounting screws (A).

Position switch roller (B) on highest (numbered) portion of cam (C).

Adjust switch to approximately 1 mm (0.04 in.) clearance (D) between switch body and switch arm.

Tighten screws (A).

NOTE: On baler equipped with soft core option, the second cam (E) is the soft core diameter cam.

CC001272


A-Screws
B-Switch roller
C-Bale size cam
D-1 mm (0.04 in.)
E-Soft core cam

CC03745,00001DB -19-08NOV00-1/1