Setting Tractor Selective Control Valves
Set tractor selective control valves to approximately 40 L/min (10.55 US gal/min) flow. This flow should provide approximately 5 seconds gate opening time. See your tractor operator's manual to make adjustments.
For 3000 Series tractors, make sure the SCV lever is in neutral position when SCV is not used.
For 5000 Series tractors, do not push SCV lever fully forward to allow lever to return to neutral when released.
For 6000 and 7000 Series tractors, adjust SCV lever for no detent, so lever returns to neutral when released.
For 8000 Series tractors, set detent time at "0".
On 590 Baler Only:
For tractors with low hydraulic flow (less than 25 L/min; 6.5 US gal/min), install orifice in bale density control valve to prevent pinching belts when closing gate. See "Installing Orifice In Tractor With Low Hydraulic Flow" in "Preparing the Baler" Section.
|