How the Soft Core Equipment Works

With Electronic Wrapping Control Monitor or Manual Twine Control Switch

Bypass on adjustable cartridge (A) is open, there is low pressure in tension cylinders. When preset soft core diameter is reached, the switch (B) is no longer activated by the cam (C). Bypass on soft core is closed and baler operates at density adjusted by operator.

With BaleMaster Control Monitor

Bypass on adjustable cartridge (A) is open, there is low pressure in tension cylinders. When the soft core diameter preset by the BaleMaster monitor is reached, bypass on soft core is closed and baler operates at density adjusted by operator.

CC007935
CC007936

55 bar soft core version

CC,570RB003462 -19-23SEP96-1/1