Removing and Installing Net Knife

causym CAUTION: Prevent personal injury by wearing gloves to handle net knife.

Note position of knife cutting edge for reinstallation.

Open net wrapping cover.

Fully extend net actuator (A) and disconnect actuator plug (B).

Remove fixing screws (C) of knife (D), then remove knife (D) from brackets (E).

Install knife (D) on brackets (E) in the same position as before removal.

Secure knife by means of fixing screws (C). Tighten screws to 55 N·m (40 lb-ft).

Reconnect actuator plug (B) and retract actuator. Close net wrapping cover.

IMPORTANT: Always carry out "Test-1" of net wrapping device check procedure after having installed net knife (see "Net Wrapping Device Check Procedure" in this Section).

CC013976
CC010016


A-Actuator
B-Actuator plug
C-Fixing screws
D-Knife
E-Bracket

CC,570RB003760 -19-01SEP98-1/1