Checking Net Actuator Retraction (Test 2)

CC013985


A-Net actuator


B-Fixing pin


C-Support


D-Side wall

IMPORTANT: Prior to carry out this test, make sure that test 1 result is "OK". Proceed to the relevant test described in this Section.

Proceed as follows:

Keep the net actuator (A) retracted.

Measure distance (X).

Remove lower actuator fixing pin (B) then fully retract actuator. Measure distance (X) once again. There must be a difference of 3 to 6 mm (0.12 to 0.24 in.).

Add or remove washers between actuator support (C) and side wall (D) to get 3 to 6 mm (0.12 to 0.24 in.) of retraction.

Install fixing pin (B).

Proceed to test 3.

CC,570RB004264 -19-01SEP98-1/1