Twine or net wrapping settings not constant with different sized bales.
|
Lower belt drive roll sensor not connected, defective or not correctly adjusted.
|
Reconnect or readjust sensor. Replace if necessary. See "BaleMaster Diagnostic Mode" and "Service" Sections.
|
|
On baler without sensor option: PTO rated speed below 540 rpm.
|
Drive baler at PTO rated speed of 540 rpm.
|
|
Bale size potentiometer not connected or defective.
|
Reconnect or replace potentiometer. See "BaleMaster Diagnostic Mode" and "Service" Sections.
|
No pictograms displayed at LCD screen when switching ON.
|
Controller fuse blown due to a reversed polarity connection of controller.
|
Connect properly and replace controller fuse. See "Service" Section.
|
|
Controller not connected.
|
Connect controller.
|
|
Battery wiring harness not correctly connected.
|
Reconnect properly. See "Preparing the Tractor" Section.
|
Erratic monitor functions.
|
Battery charge level too low.
|
Battery should deliver at least 20 A.
|
|
Battery voltage level below 7 V.
|
Monitor requires at least 12 V to function properly. Check or replace tractor battery.
|
|
Battery wiring harness not correctly connected.
|
Reconnect properly. See "Preparing the Tractor" Section.
|
|
Main switch defective.
|
Replace main switch.
|
Desired bale diameter can not be achieved.
|
Controller not set for baler model.
|
Select the right baler model. See "Operating BaleMaster Control" Section.
|
|
Bale size potentiometer not connected or defective.
|
Reconnect or replace potentiometer. See "BaleMaster Diagnostic Mode" and "Service" Sections.
|
|
Bale size fine tuned.
|
Reset to zero value. See "Operating BaleMaster Control" Section.
|
Symptom |
Problem |
Solution |
Twine arm movements not displayed on LCD screen.
|
Twine arm potentiometer not connected or defective.
|
Reconnect potentiometer, check wiring harness or replace actuator.
|
Twine arm moves to the right-hand side but does not come back (in automatic mode).
|
Twine arm potentiometer not connected or defective.
|
Reconnect potentiometer, check wiring harness or replace actuator.
|
|
Controller defective.
|
Replace controller.
|
|
Twine arm extension value tested with diagnostic mode below specified value.
|
Adjust actuator rod position to set at specified value. See "Service" Section.
|
Oversize alarm at smaller bale size than the maximum.
|
Controller not set for baler model.
|
Select the right baler model. See "Operating BaleMaster Control" Section.
|